Filtro de aire de partículas ultrafinas
$152.41-19 Piece/Pieces
$144.79≥20Piece/Pieces
Tipo de Pago: | T/T,L/C |
Incoterm: | EXW,CIF,CFR,FOB |
transporte: | Ocean,Land,Air |
Hafen: | Yantian,Guangzhou,Shanghai |
Ms. YUKA Filtration
¿Qué puedo hacer por ti?
$152.41-19 Piece/Pieces
$144.79≥20Piece/Pieces
Tipo de Pago: | T/T,L/C |
Incoterm: | EXW,CIF,CFR,FOB |
transporte: | Ocean,Land,Air |
Hafen: | Yantian,Guangzhou,Shanghai |
Modelo: HG025
Element Serve Life: 6000~8000 Hours
Clapboard: Without Clapboard
Medium Material: Fiberglass
Type: Cartridge Filter
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Filtration Performance: From 5 μm To 0.01μm
Operate Temperature: 1.5~80ºc
Transport Package: Brown Inner Box & Cardboard
Connection: Rc3/4"
Filtration Efficiency: 99.99%
Element Material: Sodium Borosilicate Glass Fiber
Maxi. Operate Pressure: 1.0 Mpa
Resistance Corrosion: Inside And Outside With 20μm Thickness
Auto Drain Parts: Anti-Collision Nut
Filtration Grade: Ulpa Filter
Element Design: Without Tie-Rod
Parallel Design: Available
Flow Rate: 1.5 M³/Min
Sight Glass: Two
Specification: Dimension: 92x 83x 255mm
Unidades de venta | : | Piece/Pieces |
Tipo de paquete | : | Caja de cartón |
Ejemplo de una imagen | : |
The file is encrypted. Please fill in the following information to continue accessing it
características y beneficios
El segundo garantiza la carcasa del filtro de aire comprimido durante quince años en las condiciones de funcionamiento recomendadas.
Filtration Grade | PF | AO | AA | AX | ACS | AR | AAR |
Particle removal (ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
Outlet oil aerosol concentration (ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Filtration performance of Particle (ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
Filtration performance of oil (ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
Element spanlife | 6000 hours | 6000 hours | 6000 hours | 6000 hours | 2000-3000 hours | 4000-6000 hours | 4000-6000 hours |
Filtration Type | Coalescence | Coalescence | Coalescence | Coalescence | Adsorption | Coalescence | Coalescence |
Airflow direction | From inside to outside | From outside to inside |
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H(Height) | A | B | C(clearance for housing) | ||
HG017 | RC1/2" | 16.7 | 1.0 | 35.3 | 92 | 83 | 265 | - | - | - |
HG025 | RC3/4" | 25 | 1.5 | 53 | 92 | 83 | 265 | - | - | - |
HG030 | RC1/2" | 30 | 1.8 | 63.6 | 92 | 83 | 285 | 17.5 | 193 | 158 |
HG035 | RC3/4" | 33.3 | 2 | 70.6 | 92 | 83 | 285 | 17.5 | 193 | 158 |
HG058 | R3/4" | 46.7 | 2.8 | 98.9 | 132 | 120 | 393.5 | 24.4 | 257.6 | 195 |
HG068 | RC1" | 60 | 3.6 | 127.1 | 132 | 93.3 | 393.5 | 24.4 | 257.6 | 195 |
HG080 | RC1" | 80 | 4.8 | 169.5 | 132 | 119.6 | 502 | 24.4 | 356.2 | 300 |
HG145 | RC1" | 120 | 7.2 | 254.2 | 132 | 19.6 | 502 | 24.4 | 356.2 | 300 |
Technical requirements | Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
¿Cómo elegir el filtro adecuado para su sistema de compresor de aire?
Cuando trabaja con compresores de aire, la purificación y filtración del aire es una parte fundamental del mantenimiento. Los filtros de aire comprimido juegan un papel importante en su sistema de compresor de aire industrial. La elección del filtro adecuado no solo aumenta la eficiencia de su unidad, sino que también puede reducir los costos de energía y proteger a sus empleados de sustancias químicas y partículas nocivas.
Sin embargo, ¿ funcionan todos los filtros de aire para su sistema de aire comprimido? Bueno, dependiendo de sus condiciones de trabajo , el proyecto que esté completando y la frecuencia con la que use su equipo, deberá tomar una decisión precisa . Esta guía detallará cómo funcionan los filtros de compresor de aire, por qué son importantes , qué tipo de filtro de compresor de aire comprar y cuándo debe reemplazarlo.
①Assess the requirements of your application. Different industry require different solution. | ||||||||
②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams. | ||||||||
③Any specific micron of filtration performance you required? | ||||||||
④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel) | ||||||||
⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment. | ||||||||
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.