Filtro de coalescencias de compresor de aire personalizado
$115- /Piece/Pieces
Tipo de Pago: | T/T |
Incoterm: | EXW |
Cantidad de pedido mínima: | 10 Piece/Pieces |
transporte: | Ocean,Air,Express |
Hafen: | Shenzhen |
Ms. YUKA Filtration
¿Qué puedo hacer por ti?
$115- /Piece/Pieces
Tipo de Pago: | T/T |
Incoterm: | EXW |
Cantidad de pedido mínima: | 10 Piece/Pieces |
transporte: | Ocean,Air,Express |
Hafen: | Shenzhen |
Modelo: YD-B220
Marca: Yuka
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Element Serve Life: 6000~8000 Hours For Pf/Ao/Aa/Ax Element Grade
Filtration Performance: 5,1,0.1,0.01 Micron, 0.001mg/M³
Maxi. Operate Pressure: 1.6mpa
Operate Temperature: 1.5~80ºc
Connection: Rc2"
Flow Rate: 12.0m³/Min
Housing Treatment: Anti-Corrosion Inside And Outside
Parts: Manual Ball Valve
O-Ring Material: Fluororubber
Color: Blue
Trademark: Yuka
Transport Package: Brown Inner Box & Cardboard
Specification: Dimension: 120 X 110 X 468 Mm
Origin: China
HS-Code: 8421399090
Clapboard: Without Clapboard
Filter Number: 1
Medium Material: Fiberglass
Efficiency: F9
Filtration Grade: Medium Filter
Type: Cartridge Filter
Unidades de venta | : | Piece/Pieces |
Tipo de paquete | : | CAJA DE CARTON |
Ejemplo de una imagen | : |
The file is encrypted. Please fill in the following information to continue accessing it
¿ H ow para seleccionar su filtro de aire apropiado?
El siguiente paso lo ayudará a elegir el filtro de Situable para su aplicación.
Si hay algún punto que no comprenda, comuníquese con los ingenieros de aplicaciones de Yuka.
* Evaluar los requisitos de su aplicación. La industria diferente requiere una solución diferente.
* ¿Qué tipo de filtración se necesita? El material de filtro coaleciente elimina los contaminantes sólidos y licuados de las corrientes de gas.
El medio de filtro de partículas elimina el sólido de las corrientes de gas. Medios absorbentes elimina los vapores de hidrocarburos de las corrientes de gas.
* ¿Alguna micrón específica de rendimiento de filtración que requiriera?
* ¿Cuáles son las condiciones de trabajo de su aplicación? Principalmente criterios de consideración:
Flujo, presión de trabajo, temperatura, pérdida de presión, material de estructura (acero inoxidable, aleación de aluminio, acero suave, acero al carbono)
* Casa de flujo de filtro desde ¿cuánto SCFM? La caída de presión debe ser menor que ** bar? Para ahorrar el costo y proteger el medio ambiente.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Model | Pipe Size | Max Flow rates | Dimension(mm) | |||||||
L/S | m³/min | cfm | W (Width) | D (Diameter) | H (Height) | A | B | C(clearance for housing) | ||
YD-B017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 239 | 40 | 197 | 182 |
YD-B030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 273 | 40 | 232 | 217 |
YD-B058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 349 | 55 | 290 | 264 |
YD-B068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 369 | 55 | 310 | 264 |
YD-B080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B145 | RC1-1/2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 468 | 55 | 410 | 357 |
YD-B220 | RC2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B260 | RC2-1/2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 593 | 64 | 526 | 485 |
YD-B330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 873 | 64 | 806 | 760 |
YD-B405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 637 | 78 | 558 | 508 |
YD-B620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 892 | 78 | 815 | 762 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.76 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.